Abstract

Receiver operating characteristic (ROC) methodology is widely used in evaluating medical imaging modalities. While appropriate in some cases, it has several drawbacks when the detection task, e.g., nodule detection, involves localizing the abnormality. Free‐response receiver operating characteristic (FROC) methodology offers a more natural framework to describe observer performance in such studies and has other advantages. Due to the lack of a statistical analysis procedure comparable to the maximum likelihood procedure (rocfit program) available for ROC studies, the FROC method has not gained widespread acceptance. This work presents and solves a two parameter model for the statistical analysis of FROC data. The model assumes that the probability density of the signal stimuli is normally distributed, as is the probability density for producing one or more false positives per image. A program (frocfit) is described for estimating the parameters and their uncertainties from experimental data. An index of performance is proposed to quantify observer performance in FROC experiments. Application of this methodology to several FROC data sets produced good to excellent fits.

Number of times cited according to CrossRef: 145

  • Receiver Operating Characteristic (ROC) Analysis of Image Search-and-Localize Tasks, Academic Radiology, 10.1016/j.acra.2019.12.020, (2020).
  • Computer-Aided Tumor Detection in Automated Breast Ultrasound using a 3-D Convolutional Neural Network, Computer Methods and Programs in Biomedicine, 10.1016/j.cmpb.2020.105360, (105360), (2020).
  • A framework to analyze decision strategies for multi-band spectrum sensing in cognitive radios, Physical Communication, 10.1016/j.phycom.2020.101139, (101139), (2020).
  • Multi-View Information Fusion in Mammograms: A Comprehensive Overview, Information Fusion, 10.1016/j.inffus.2019.05.001, (2019).
  • X-Ray Enhancement Based on Component Attenuation, Contrast Adjustment, and Image Fusion, IEEE Transactions on Image Processing, 10.1109/TIP.2018.2865637, 28, 1, (127-141), (2019).
  • Fast ScanNet: Fast and Dense Analysis of Multi-Gigapixel Whole-Slide Images for Cancer Metastasis Detection, IEEE Transactions on Medical Imaging, 10.1109/TMI.2019.2891305, 38, 8, (1948-1958), (2019).
  • Automatic Lung Nodule Detection in CT Images Using Convolutional Neural Networks, IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences, 10.1587/transfun.E102.A.1364, E102.A, 10, (1364-1373), (2019).
  • Multi-signal detection and parameter estimation fusion with an improved utility function, Digital Signal Processing, 10.1016/j.dsp.2019.102641, (102641), (2019).
  • Detection accuracy of maxillary sinus floor septa in panoramic radiographs using CBCT as gold standard: a multi-observer receiver operating characteristic (ROC) study, Clinical Oral Investigations, 10.1007/s00784-018-2414-1, 23, 1, (99-105), (2018).
  • Evaluation of diagnostic accuracy in free-response detection-localization tasks using ROC tools, Statistical Methods in Medical Research, 10.1177/0962280218776683, 28, 6, (1808-1825), (2018).
  • A Short History of Image Perception in Medical Radiology, The Handbook of Medical Image Perception and Techniques, 10.1017/9781108163781, (11-22), (2018).
  • Evaluation of CAD and Radiomic Tools, The Handbook of Medical Image Perception and Techniques, 10.1017/9781108163781, (389-406), (2018).
  • undefined, 2018 IEEE Winter Conference on Applications of Computer Vision (WACV), 10.1109/WACV.2018.00065, (539-546), (2018).
  • A Solitary Feature-Based Lung Nodule Detection Approach for Chest X-Ray Radiographs, IEEE Journal of Biomedical and Health Informatics, 10.1109/JBHI.2017.2661805, 22, 2, (516-524), (2018).
  • Automatic breast tumor detection in ABVS images based on convolutional neural network and superpixel patterns, Neural Computing and Applications, 10.1007/s00521-017-3138-x, 31, 4, (1069-1081), (2017).
  • The Reproducibility of Changes in Diagnostic Figures of Merit Across Laboratory and Clinical Imaging Reader Studies, Academic Radiology, 10.1016/j.acra.2017.05.007, 24, 11, (1436-1446), (2017).
  • undefined, 2017 IEEE International Conference on Image Processing (ICIP), 10.1109/ICIP.2017.8296646, (2069-2073), (2017).
  • Fully automatic detection of lung nodules in CT images using a hybrid feature set, Medical Physics, 10.1002/mp.12273, 44, 7, (3615-3629), (2017).
  • Quantification of hazard prediction ability at hazard prediction training (Kiken-Yochi Training: KYT) by free-response receiver-operating characteristic (FROC) analysis, Radiological Physics and Technology, 10.1007/s12194-016-0374-1, 10, 1, (106-112), (2016).
  • Technical Note: Display window setting: An important factor for detecting subtle but clinically relevant artifacts in daily CT quality control, Medical Physics, 10.1118/1.4966698, 43, 12, (6413-6417), (2016).
  • On the meaning of the weighted alternative free‐response operating characteristic figure of merit, Medical Physics, 10.1118/1.4947125, 43, 5, (2548-2557), (2016).
  • Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in Canines, Radiology, 10.1148/radiol.2015150606, 278, 2, (413-421), (2016).
  • Dispersive Flies Optimisation and Medical Imaging, Recent Advances in Computational Optimization, 10.1007/978-3-319-21133-6_11, (183-203), (2016).
  • Tracking Virus Particles in Fluorescence Microscopy Images Using Multi-Scale Detection and Multi-Frame Association, IEEE Transactions on Image Processing, 10.1109/TIP.2015.2458174, 24, 11, (4122-4136), (2015).
  • Observer Performance in the Detection and Classification of Malignant Hepatic Nodules and Masses with CT Image-Space Denoising and Iterative Reconstruction, Radiology, 10.1148/radiol.2015141991, 276, 2, (465-478), (2015).
  • Modeling false positive error making patterns in radiology trainees for improved mammography education, Journal of Biomedical Informatics, 10.1016/j.jbi.2015.01.007, 54, (50-57), (2015).
  • Observer performance for adaptive, image-based denoising and filtered back projection compared to scanner-based iterative reconstruction for lower dose CT enterography, Abdominal Imaging, 10.1007/s00261-015-0384-1, 40, 5, (1050-1059), (2015).
  • Multi-Dimensional Tumor Detection in Automated Whole Breast Ultrasound Using Topographic Watershed, IEEE Transactions on Medical Imaging, 10.1109/TMI.2014.2315206, 33, 7, (1503-1511), (2014).
  • Computer-Aided Diagnosis Improves Detection of Small Intracranial Aneurysms on MRA in a Clinical Setting, American Journal of Neuroradiology, 10.3174/ajnr.A3996, 35, 10, (1897-1902), (2014).
  • Automated pulmonary nodule detection based on three-dimensional shape-based feature descriptor, Computer Methods and Programs in Biomedicine, 10.1016/j.cmpb.2013.08.015, 113, 1, (37-54), (2014).
  • Feature Selection for the Automated Detection of Metaphase Chromosomes: Performance Comparison Using a Receiver Operating Characteristic Method, Analytical Cellular Pathology, 10.1155/2014/565392, 2014, (1-9), (2014).
  • Cluster Size Statistic and Cluster Mass Statistic: Two Novel Methods for Identifying Changes in Functional Connectivity Between Groups or Conditions, PLoS ONE, 10.1371/journal.pone.0098697, 9, 6, (e98697), (2014).
  • Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT, Investigative Radiology, 10.1097/RLI.0b013e31827efc3a, (1), (2013).
  • undefined, 2013 IEEE Applied Imagery Pattern Recognition Workshop (AIPR), 10.1109/AIPR.2013.6749326, (1-9), (2013).
  • A Brief History of Free-Response Receiver Operating Characteristic Paradigm Data Analysis, Academic Radiology, 10.1016/j.acra.2013.03.001, 20, 7, (915-919), (2013).
  • Subject‐centered free‐response ROC (FROC) analysis, Medical Physics, 10.1118/1.4799843, 40, 5, (2013).
  • Evaluation of computer‐aided detection and diagnosis systems, Medical Physics, 10.1118/1.4816310, 40, 8, (2013).
  • undefined, 2012 IEEE International Conference on Bioinformatics and Biomedicine Workshops, 10.1109/BIBMW.2012.6470317, (280-287), (2012).
  • Introduction to Task-Based Assessment of Image Quality for Investigators Employing Monte Carlo Simulation of Imaging Systems, Monte Carlo Calculations in Nuclear Medicine, Second Edition, 10.1201/b13073-16, (287-312), (2012).
  • Whole Breast Lesion Detection Using Naive Bayes Classifier for Portable Ultrasound, Ultrasound in Medicine & Biology, 10.1016/j.ultrasmedbio.2012.07.006, 38, 11, (1870-1880), (2012).
  • undefined, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 10.1109/EMBC.2012.6346947, (4422-4425), (2012).
  • Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA, Academic Radiology, 10.1016/j.acra.2011.12.016, 19, 4, (463-477), (2012).
  • PET Energy-Based Scatter Estimation in the Presence of Randoms, and Image Reconstruction With Energy-Dependent Scatter and Randoms Corrections, IEEE Transactions on Nuclear Science, 10.1109/TNS.2012.2201170, 59, 5, (1958-1966), (2012).
  • Computerized Detection of Lung Nodules on Chest Radiographs, Machine Learning in Computer-Aided Diagnosis, 10.4018/978-1-4666-0059-1.ch006, (122-144), (2012).
  • Computer-Aided Detection Scheme for Sentinel Lymph Nodes in Lymphoscintigrams using Symmetrical Property Around Mapped Injection Point, Journal of Digital Imaging, 10.1007/s10278-011-9396-8, 25, 1, (148-154), (2011).
  • Biplane Correlation Imaging: A Feasibility Study Based on Phantom and Human Data, Journal of Digital Imaging, 10.1007/s10278-011-9392-z, 25, 1, (137-147), (2011).
  • New Developments in Observer Performance Methodology in Medical Imaging, Seminars in Nuclear Medicine, 10.1053/j.semnuclmed.2011.07.001, 41, 6, (401-418), (2011).
  • Digital magnification mammography with matched incident exposure: physical imaging properties and detectability of simulated microcalcifications, Radiological Physics and Technology, 10.1007/s12194-011-0116-3, 4, 2, (156-163), (2011).
  • Free-Response ROC Analysis, Statistical Evaluation of Diagnostic Performance, 10.1201/b11031-12, (163-200), (2011).
  • A random-sum Wilcoxon statistic and its application to analysis of ROC and LROC data, Journal of Statistical Planning and Inference, 10.1016/j.jspi.2010.06.011, 141, 1, (335-344), (2011).
  • Development and evaluation of a computer‐aided diagnostic scheme for lung nodule detection in chest radiographs by means of two‐stage nodule enhancement with support vector classification, Medical Physics, 10.1118/1.3561504, 38, 4, (1844-1858), (2011).
  • Nonparametric signal detectability evaluation using an exponential transformation of the FROC curve, Medical Physics, 10.1118/1.3633938, 38, 10, (5690-5702), (2011).
  • Quantitative Comparison of Spot Detection Methods in Fluorescence Microscopy, IEEE Transactions on Medical Imaging, 10.1109/TMI.2009.2025127, 29, 2, (282-301), (2010).
  • An Approach to Comparing Accuracies of Two Flair MR Sequences in the Detection of Multiple Sclerosis Lesions in the Brain in the Absence of Gold Standard, Academic Radiology, 10.1016/j.acra.2010.01.019, 17, 6, (686-695), (2010).
  • Consistency of methods for analysing location-specific data, Radiation Protection Dosimetry, 10.1093/rpd/ncq030, 139, 1-3, (52-56), (2010).
  • undefined, AIAA Guidance, Navigation, and Control Conference, 10.2514/6.2010-7863, (2010).
  • A status report on free-response analysis, Radiation Protection Dosimetry, 10.1093/rpd/ncp305, 139, 1-3, (20-25), (2010).
  • Multiclass detection of cells in multicontrast composite images, Computers in Biology and Medicine, 10.1016/j.compbiomed.2009.11.013, 40, 2, (168-178), (2010).
  • Ideal AFROC and FROC Observers, IEEE Transactions on Medical Imaging, 10.1109/TMI.2009.2031840, 29, 2, (375-386), (2010).
  • undefined, IEEE Nuclear Science Symposuim & Medical Imaging Conference, 10.1109/NSSMIC.2010.5874350, (3009-3014), (2010).
  • undefined, 2009 IEEE Applied Imagery Pattern Recognition Workshop (AIPR 2009), 10.1109/AIPR.2009.5466318, (1-8), (2009).
  • Commercially Available Computer-Aided Detection System for Pulmonary Nodules on Thin-Section Images Using 64 Detectors-Row CT, Academic Radiology, 10.1016/j.acra.2009.01.030, 16, 8, (924-933), (2009).
  • Quantitative Kinetic Analysis of Lung Nodules Using the Temporal Subtraction Technique in Dynamic Chest Radiographies Performed with a Flat Panel Detector, Journal of Digital Imaging, 10.1007/s10278-008-9116-1, 22, 2, (126-135), (2008).
  • References, Journal of the ICRU, 10.1093/jicru/ndn017, 8, 1, (57-62), (2008).
  • Multiclass cell detection in bright field images of cell mixtures with ECOC probability estimation, Image and Vision Computing, 10.1016/j.imavis.2007.07.004, 26, 4, (578-591), (2008).
  • Validation and Statistical Power Comparison of Methods for Analyzing Free-response Observer Performance Studies, Academic Radiology, 10.1016/j.acra.2008.07.018, 15, 12, (1554-1566), (2008).
  • Colon polyp detection using smoothed shape operators: Preliminary results, Medical Image Analysis, 10.1016/j.media.2007.08.001, 12, 2, (99-119), (2008).
  • Evaluation of Computer-aided Diagnosis (CAD) Software for the Detection of Lung Nodules on Multidetector Row Computed Tomography (MDCT), Academic Radiology, 10.1016/j.acra.2008.06.009, 15, 12, (1505-1512), (2008).
  • Operating characteristics predicted by models for diagnostic tasks involving lesion localization, Medical Physics, 10.1118/1.2820902, 35, 2, (435-445), (2008).
  • On comparing methods for discriminating between actually negative and actually positive subjects with FROC type data, Medical Physics, 10.1118/1.2890410, 35, 4, (1547-1558), (2008).
  • Automated breast mass detection in 3D reconstructed tomosynthesis volumes: A featureless approach, Medical Physics, 10.1118/1.2953562, 35, 8, (3626-3636), (2008).
  • KDD cup 2008 and the workshop on mining medical data, ACM SIGKDD Explorations Newsletter, 10.1145/1540276.1540288, 10, 2, (34-38), (2008).
  • A quantitative method for evaluating the detectability of lesions in digital mammography, Radiation Protection Dosimetry, 10.1093/rpd/ncn049, 129, 1-3, (214-218), (2008).
  • ROC analysis in medical imaging: a tutorial review of the literature, Radiological Physics and Technology, 10.1007/s12194-007-0002-1, 1, 1, (2-12), (2007).
  • The identification of complete domains within protein sequences using accurate E-values for semi-global alignment, Nucleic Acids Research, 10.1093/nar/gkm414, 35, 14, (4678-4685), (2007).
  • Computer-aided detection system for clustered microcalcifications: comparison of performance on full-field digital mammograms and digitized screen-film mammograms, Physics in Medicine and Biology, 10.1088/0031-9155/52/4/008, 52, 4, (981-1000), (2007).
  • Spatial Localization Accuracy of Radiologists in Free-Response Studies: Inferring Perceptual FROC Curves from Mark-Rating Data, Academic Radiology, 10.1016/j.acra.2006.10.015, 14, 1, (4-18), (2007).
  • Free-response operator characteristic models for visual search, Physics in Medicine and Biology, 10.1088/0031-9155/52/10/L01, 52, 10, (L1-L3), (2007).
  • “Binary” and “Non-Binary” Detection Tasks: Are Current Performance Measures Optimal?, Academic Radiology, 10.1016/j.acra.2007.03.014, 14, 7, (871-876), (2007).
  • Detection and Localization in Test Accuracy: A Bayesian Perspective, Communications in Statistics - Theory and Methods, 10.1080/03610920601126027, 36, 8, (1555-1564), (2007).
  • Computer-Aided Diagnosis Scheme for Detection of Lacunar Infarcts on MR Images, Academic Radiology, 10.1016/j.acra.2007.09.012, 14, 12, (1554-1561), (2007).
  • Computer-Aided Diagnosis for Improved Detection of Lung Nodules by Use of Posterior-Anterior and Lateral Chest Radiographs, Academic Radiology, 10.1016/j.acra.2006.09.057, 14, 1, (28-37), (2007).
  • Nonparametric ROC and LROC analysis, Medical Physics, 10.1118/1.2717407, 34, 5, (1556-1564), (2007).
  • Evaluating computer‐aided detection algorithms, Medical Physics, 10.1118/1.2736289, 34, 6Part1, (2024-2038), (2007).
  • Development of a fully automatic scheme for detection of masses in whole breast ultrasound images, Medical Physics, 10.1118/1.2795825, 34, 11, (4378-4388), (2007).
  • Detection of clustered microcalcifications in small field digital mammography, Computer Methods and Programs in Biomedicine, 10.1016/j.cmpb.2005.10.002, 81, 1, (56-65), (2006).
  • Analysis of Location Specific Observer Performance Data: Validated Extensions of the Jackknife Free-Response (JAFROC) Method, Academic Radiology, 10.1016/j.acra.2006.06.016, 13, 10, (1187-1193), (2006).
  • Automatic detection of unstained viable cells in bright field images using a support vector machine with an improved training procedure, Computers in Biology and Medicine, 10.1016/j.compbiomed.2004.12.002, 36, 4, (339-362), (2006).
  • Analysis of proposed three-class classification decision rules in terms of the ideal observer decision rule, Journal of Mathematical Psychology, 10.1016/j.jmp.2006.05.004, 50, 5, (478-487), (2006).
  • Small nodule detectability evaluation using a generalized scan-statistic model, Physics in Medicine and Biology, 10.1088/0031-9155/51/23/020, 51, 23, (6225-6244), (2006).
  • A search model and figure of merit for observer data acquired according to the free-response paradigm, Physics in Medicine and Biology, 10.1088/0031-9155/51/14/012, 51, 14, (3449-3462), (2006).
  • Diagnostic accuracy of fracture detection in suspected non-accidental injury: the effect of edge enhancement and digital display on observer performance, Clinical Radiology, 10.1016/j.crad.2005.09.004, 61, 2, (163-173), (2006).
  • Computer‐aided diagnostic scheme for the detection of lung nodules on chest radiographs: Localized search method based on anatomical classification, Medical Physics, 10.1118/1.2208739, 33, 7Part1, (2642-2653), (2006).
  • Computer-Aided Detection and Diagnosis in Mammography, Handbook of Image and Video Processing, 10.1016/B978-012119792-6/50130-3, (1195-1217), (2005).
  • Biomedical Imaging Research Opportunities Workshop II: Report and Recommendations, Radiology, 10.1148/radiol.2362041876, 236, 2, (389-403), (2005).
  • Perceptually Based FROC Analysis1, Academic Radiology, 10.1016/j.acra.2005.06.015, 12, 12, (1567-1574), (2005).
  • Estimation and Comparison of CAD System Performance in Clinical Settings1, Academic Radiology, 10.1016/j.acra.2005.02.005, 12, 6, (687-694), (2005).
  • ROC Analysis, American Journal of Roentgenology, 10.2214/ajr.184.2.01840364, 184, 2, (364-372), (2005).
  • Free-Response Receiver Operating Characteristic Evaluation of Lossy JPEG2000 and Object-based Set Partitioning in Hierarchical Trees Compression of Digitized Mammograms, Radiology, 10.1148/radiol.2372040996, 237, 2, (450-457), (2005).
  • Diagnosis of Subsegmental Pulmonary Emboli, Journal of Thoracic Imaging, 10.1097/01.rti.0000155044.82156.ad, 20, 1, (24-31), (2005).
  • See more