Volume 30, Issue 6 p. 1254-1263
Radiation therapy physics

A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing

Daniel A. Low

Daniel A. Low

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Michelle Nystrom

Michelle Nystrom

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Eugene Kalinin

Eugene Kalinin

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Parag Parikh

Parag Parikh

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
James F. Dempsey

James F. Dempsey

Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, Florida

Search for more papers by this author
Jeffrey D. Bradley

Jeffrey D. Bradley

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Sasa Mutic

Sasa Mutic

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Sasha H. Wahab

Sasha H. Wahab

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Tareque Islam

Tareque Islam

Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Gary Christensen

Gary Christensen

Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa

Search for more papers by this author
David G. Politte

David G. Politte

Department of Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
Bruce R. Whiting

Bruce R. Whiting

Department of Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri 63110

Search for more papers by this author
First published: 30 May 2003
Citations: 386

Abstract

Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity-modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath-hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four-dimensional (4-D) image set, where tidal lung volume is the additional dimension. An analysis of this 4-D data leads to methods for digital-spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4-D image set is generated by sorting free-breathing multislice CT scans according to user-defined tidal-volume bins. A multislice CT scanner is operated in the ciné mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital-spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 urn:x-wiley:00942405:media:mp6230:mp6230-math-0001 An analysis of sagittal and coronal images demonstrated relatively small (<1 cm) motion artifacts along the diaphragm, even for tidal volumes where the rate of breathing motion is greatest. While still under development, this technology has the potential for revolutionizing the radiotherapy treatment planning for the thorax and upper abdomen.